The EMC laboratory/Equipment

(Difference between revisions)
Jump to: navigation, search
(Teseq DC-LISN-M2-100)
(LISN's)
Line 17: Line 17:
  
 
== LISN's ==
 
== LISN's ==
 +
=== Schaffner (-Chase EMC Ltd.) MN2050D ===
 +
 
=== Teseq DC-LISN-M2-100 ===
 
=== Teseq DC-LISN-M2-100 ===
 
[[File:DC_LISN_M2_100.jpg]]<br>
 
[[File:DC_LISN_M2_100.jpg]]<br>

Revision as of 09:02, 20 May 2019

Contents

AC power sources

Triphase

  • This 15kW AC source is intended to provide a grid voltage compliant to IEC 61000-4-7. She is well configurable and allow a lot of scenarios (AC source, DC source, harmonic generation, ...)
  • To use this AC source, we recommanded to do following steps:


  1. Start the power source
  2. Start the control PC
  3. Connect to the webserver of the control PC


More information available on Follow instructions of simplified user manual page 14 (Interface web)


LISN's

Schaffner (-Chase EMC Ltd.) MN2050D

Teseq DC-LISN-M2-100

DC LISN M2 100.jpg
(picture source Teseq)
Line impedance Stabilization Network to measure conducted emissions disturbances on DC power ports of photovoltaic inverters.

  • Frequency range: 150 kHz to 30 MHz
  • Continuous operating current: 100 A (150 A for 30 minutes)
  • Impedance: 150 Ω in common-mode - 100 Ω in differential-mode
Personal tools
Namespaces
Variants
Actions
Navigation
Laws & standards
The EMC laboratory
Standards at library
Browse
Toolbox