The EMC laboratory/Equipment
From EMC
(Difference between revisions)
(→Teseq DC-LISN-M2-100) |
(→Schwarzbeck Mess-Elektronik NNLA 8120) |
||
(9 intermediate revisions by one user not shown) | |||
Line 17: | Line 17: | ||
== LISN's == | == LISN's == | ||
+ | === Schaffner (-Chase EMC Ltd.) MN2050D === | ||
+ | V-AMN to measure conducted emissions disturbances on AC port (single phase) or DC port | ||
+ | * Frequency range: ... | ||
+ | * Continuous operating current: ... | ||
+ | * Impedance: | ||
+ | === Schwarzbeck Mess-Elektronik NNLA 8120 === | ||
+ | V-AMN to measure conducted emissions disturbances on AC port (tree phases + neutral) | ||
+ | * Frequency range: 9 kHz to 30 MHz | ||
+ | * Continuous operating current: 4 X 16 A | ||
+ | * Impedance: 50 <math>{\Omega}</math> || 50 <math>{\mu}</math> + 5 <math>{\Omega}</math> | ||
+ | |||
=== Teseq DC-LISN-M2-100 === | === Teseq DC-LISN-M2-100 === | ||
− | [[File:DC_LISN_M2_100.jpg]] | + | [[File:DC_LISN_M2_100.jpg]]<br> |
+ | ([https://www.teseq.com/news/2013/DC-LISN-M2-100.php picture source Teseq])<br> | ||
Line impedance Stabilization Network to measure conducted emissions disturbances on DC power ports of photovoltaic inverters. | Line impedance Stabilization Network to measure conducted emissions disturbances on DC power ports of photovoltaic inverters. | ||
* Frequency range: 150 kHz to 30 MHz | * Frequency range: 150 kHz to 30 MHz | ||
* Continuous operating current: 100 A (150 A for 30 minutes) | * Continuous operating current: 100 A (150 A for 30 minutes) | ||
− | * Impedance: 150 <math>{\Omega}</math> in common-mode - 100 <math>{\Omega}</math> | + | * Impedance: 150 <math>{\Omega}</math> in common-mode - 100 <math>{\Omega}</math> in differential-mode |
Latest revision as of 15:43, 8 July 2019
|
AC power sources
Triphase
- This 15kW AC source is intended to provide a grid voltage compliant to IEC 61000-4-7. She is well configurable and allow a lot of scenarios (AC source, DC source, harmonic generation, ...)
- To use this AC source, we recommanded to do following steps:
- Start the power source
- Start the control PC
- Connect to the webserver of the control PC
More information available on Follow instructions of simplified user manual page 14 (Interface web)
LISN's
Schaffner (-Chase EMC Ltd.) MN2050D
V-AMN to measure conducted emissions disturbances on AC port (single phase) or DC port
- Frequency range: ...
- Continuous operating current: ...
- Impedance:
Schwarzbeck Mess-Elektronik NNLA 8120
V-AMN to measure conducted emissions disturbances on AC port (tree phases + neutral)
- Frequency range: 9 kHz to 30 MHz
- Continuous operating current: 4 X 16 A
- Impedance: 50 Ω || 50 μ + 5 Ω
Teseq DC-LISN-M2-100
(picture source Teseq)
Line impedance Stabilization Network to measure conducted emissions disturbances on DC power ports of photovoltaic inverters.
- Frequency range: 150 kHz to 30 MHz
- Continuous operating current: 100 A (150 A for 30 minutes)
- Impedance: 150 Ω in common-mode - 100 Ω in differential-mode