The EMC laboratory/Equipment

From EMC
Revision as of 12:57, 15 April 2019 by Blaise.evequoz (Talk | contribs)
Jump to: navigation, search

Contents

AC power sources

Triphase

  • This 15kW AC source is intended to provide a grid voltage compliant to IEC 61000-4-7. She is well configurable and allow a lot of scenarios (AC source, DC source, harmonic generation, ...)
  • To use this AC source, we recommanded to do following steps:


  1. Start the power source
  2. Start the control PC
  3. Connect to the webserver of the control PC


More information available on Follow instructions of simplified user manual page 14 (Interface web)


LISN's

Teseq DC-LISN-M2-100

Line impedance Stabilization Network to measure conducted emissions disturbances on DC power ports of photovoltaic inverters.

  • Frequency range: 150 kHz to 30 MHz
  • Continuous operating current: 100 A (150 A for 30 minutes)
  • Impedance: 150 Ω in common-mode - 100 Ω