The personal of EMC laboratory will achieve following measurment
 
The personal of EMC laboratory will achieve following measurment
  
* Emission of enclosure (to perform IEC 61000-6-3)
+
 
 +
 
 +
 
 +
 
 +
 
 +
 
 +
 
 +
 
 +
 
 +
 
 +
 
 +
 
 +
 
 +
 
 +
= Emission - Enclosure =
 +
The well known emission procedure is achievable in the SAC. The keywords
 +
to retain are:
 +
* Respect to IEC 61000-6-3
 +
* 3 meter chamber
 +
* horizontal or vertical polarization
 +
* Quasi peak measurment
 +
* only 1 meter elevation
 +
* need manual rotation of EUT
 +
 
 +
For generic standard IEC 61000-6-3, the level are displayed on the next figure
 +
(The limits for 10 meters are informative, not achievable in the EMC laboratory).<br>
 +
[[File:Emission_Enclosure_Generic_Limits_@_3_meters.svg]]
 +
 
 +
 
 +
= Emission - AC Port =

Latest revision as of 10:53, 26 September 2017

Contents

Usually, the tests are realized from non invasive to invasive over EUT. The personal of EMC laboratory will achieve following measurment








Emission - Enclosure

The well known emission procedure is achievable in the SAC. The keywords to retain are:

  • Respect to IEC 61000-6-3
  • 3 meter chamber
  • horizontal or vertical polarization
  • Quasi peak measurment
  • only 1 meter elevation
  • need manual rotation of EUT

For generic standard IEC 61000-6-3, the level are displayed on the next figure (The limits for 10 meters are informative, not achievable in the EMC laboratory).