HiRel/CanSat/Slave Power

(Difference between revisions)
Jump to: navigation, search
(Power usage)
Line 1: Line 1:
 
{{TOC right}}
 
{{TOC right}}
 +
 +
{|class=wikitable
 +
|-
 +
! Type || CanSat Slave Power || Schematic || Description
 +
|-
 +
| V1.0 || [[TBD|200px|CanSat Slave Power V1.0]] || [[Media:P-CAD EDA - CanSat Slave Power schematic.pdf|CanSat Slave Power v1.0 Schematic PDF]] ||
 +
|-
 +
|}
  
 
= Power inputs =
 
= Power inputs =

Revision as of 19:14, 23 January 2015

Contents

Type CanSat Slave Power Schematic Description
V1.0 200px|CanSat Slave Power V1.0 CanSat Slave Power v1.0 Schematic PDF

Power inputs

The CanSat system has 3 possible power sources:

  • a mini-USB connector on the power supply board
  • a battery connector on the power supply board
  • a micro-USB connector on the microprocessor board

Only one of these should power the system with 5 V. Jumpers are provided in order to select the actual power source. This 5 V is distributed to all the boards on the top connector disk.

Cansat-power.svg

The power board generates 3.3 V from 5 V. The 3.3 V is distributed to all the boards on the bottom connector disk.

Power usage

The 5 V is used by:

  • the power supply board for generating the 3.3 V
  • the sensors board for the Max11300 together with the temperature and pressure sensors

The precision of the 5 V is given by the components' requirements:

  • the DC/DC converter needs 2.9 V ÷ 5.5 V
  • the Max11300 mixed-mode I/O interface needs 4.75 V ÷ 5.25 V
  • the pressure sensor needs 4.75 V ÷ 5.25 V
  • the temperature sensor needs 2.5 V ÷ 5.5 V

The 3.3 V is used by: