Kart/sensor board

(Difference between revisions)
Jump to: navigation, search
(Test pins)
(9 intermediate revisions by 2 users not shown)
Line 29: Line 29:
 
=== Hall sensors ===
 
=== Hall sensors ===
  
The sensor connectors are located in the I/O board's middle row.
+
The [[kart/sensors/SS311PT|Hall sensors]] connectors are located in the I/O board's middle row,
 +
on the side opposite to the 5-pin connector.
 
The sensor cable is to be connected as:
 
The sensor cable is to be connected as:
 
:{| cellpadding="3" cellspacing="0" border="1"
 
:{| cellpadding="3" cellspacing="0" border="1"
Line 36: Line 37:
 
|-
 
|-
 
| red
 
| red
| 3.3 V or 5 V power supply
+
| 3.3 V power supply
 
|-
 
|-
 
| brown
 
| brown
Line 47: Line 48:
 
=== Ultrasound ranger ===
 
=== Ultrasound ranger ===
  
The sensor connectors are located in the I/O board's middle row.
+
The [[Kart/sensors/HCSR04|ultrasound ranger]] connectors are located on the side of the I/O board's middle row.
 
It is the single 5-pin connector.
 
It is the single 5-pin connector.
 
The sensor cable is to be connected as:
 
The sensor cable is to be connected as:
Line 69: Line 70:
 
=== Proximity sensors ===
 
=== Proximity sensors ===
  
The sensor connectors are located in the I/O board's side row.
+
The [[kart/sensors/VCNL4000|proximity sensor]] connectors are located in the I/O board's side row.
  
 
The sensor cable is to be connected as:
 
The sensor cable is to be connected as:
Line 97: Line 98:
 
The power supply is connected directly to the 12 V battery packs.
 
The power supply is connected directly to the 12 V battery packs.
 
The resistor is connected between the power supply and the LED.
 
The resistor is connected between the power supply and the LED.
The LED is connected between the resistor and the ground.
+
The LED is connected between the resistor and the [[Media:Kart ULN2003.pdf|switch]] to the ground.
  
 
== FPGA design ==
 
== FPGA design ==
Line 132: Line 133:
 
Draw the schematics of the <code>ultrasoundRanger</code> block.
 
Draw the schematics of the <code>ultrasoundRanger</code> block.
 
}}
 
}}
 +
 +
== Test pins ==
 +
 +
The basic sensor design leaves 5 free pins.
 +
Pins 13 to 15 are foreseen for test outputs.
 +
Pins 10 to 11 are foreseen for test outputs with a divider by&nbsp;2 for pulses.
  
 
[[Category:Kart]]
 
[[Category:Kart]]

Revision as of 12:54, 1 July 2020

Contents

The sensor board provides different I/Os to the system. The schematics provides detailed information about it.

FPGA motherboard

Inputs and outputs

End of turn switch

The end of turn switch is located in the I/O board's middle row. It is the 4-pin connector closest to the 5-pin connector. The switch cable is to be connected as:

cable pin
green 5 V power supply
yellow input

The input has a pull-down resistor. Closing the switch brings a logic '1'.

Hall sensors

The Hall sensors connectors are located in the I/O board's middle row, on the side opposite to the 5-pin connector. The sensor cable is to be connected as:

cable pin
red 3.3 V power supply
brown sensor signal
black ground

Ultrasound ranger

The ultrasound ranger connectors are located on the side of the I/O board's middle row. It is the single 5-pin connector. The sensor cable is to be connected as:

cable pin
red 5 V power supply
yellow measurement start (trig)
green distance signal (echo, in)
black ground

Proximity sensors

The proximity sensor connectors are located in the I/O board's side row.

The sensor cable is to be connected as:

cable pin
orange 3.3 V power supply
yellow SDA
green SCL
blue ground

LED outputs

The board has 4 LED outputs which can also be used for other purposes, such as buzzers.

The outputs have a common power supply, 2 resistor mount holes and a 2-pin LED connector located on the I/O board's bottom row.

The power supply is connected directly to the 12 V battery packs. The resistor is connected between the power supply and the LED. The LED is connected between the resistor and the switch to the ground.

FPGA design

One or two Hall sensors are used to track the distance driven by the kart. An ultrasound ranger can detect if there is an obstacle at the front of the kart.

To begin with, the design environment has to be downloaded. It comprises the sensorsInterface block which contains the provided I2C bus interface, an empty hallCounters block and an empty ultrasoundRanger block which are to be designed.

Hall sensor

The hall sensor has a Schmitt-trigger output. This means that it has to "see" a north and then a south magnetic pole in order to switch its output.

The block receives a hallPulses signal array, one per hall pulse sensor. For each of these inputs, it requires a counter. The counter values are concatenated to build the position output.


View-pim-tasks.png

Draw the schematics of the hallCounters block.

Ultrasound ranger

The ultrasound ranger receives a trigger signal, startMeasure, and sends an ultrasound pulse. Once the pulse is sent, the sensor drives distancePulse to '1' as long as it hasn't received any echo.

The circuit has to count the length of the sequence in terms of clock pulses and returns the value on distance.


View-pim-tasks.png

Draw the schematics of the ultrasoundRanger block.

Test pins

The basic sensor design leaves 5 free pins. Pins 13 to 15 are foreseen for test outputs. Pins 10 to 11 are foreseen for test outputs with a divider by 2 for pulses.