Hardware/Parallelport/heb inverter
From UIT
(Difference between revisions)
(→Dead time) |
(→Dead time) |
||
Line 22: | Line 22: | ||
{|class=wikitable | {|class=wikitable | ||
|- | |- | ||
− | ! bit nb || dead time || current [mA] | + | ! bit nb || dead time [ns] || current [mA] |
|- | |- | ||
− | | 3 || | + | | 3 || 121 || 860 |
|- | |- | ||
− | | 4 || | + | | 4 || 242 || 170 |
|- | |- | ||
− | | 5 || | + | | 5 || 485 || 75 |
|- | |- | ||
− | | 5 || | + | | 5 || 970 || 70 |
|} | |} | ||
[[Category:Hardware]] [[Category:Parallelport]] [[Category:HEB]] | [[Category:Hardware]] [[Category:Parallelport]] [[Category:HEB]] |
Latest revision as of 14:59, 17 January 2022
|
Inverter board
The board was designed for the ETE ELN-inverter lab.
It receives 4 PWM signals to drive an H-Bridge. The bridge is followed by an LC-lowpass and a transformer.
A sigma-delta ADC reads the LC filter output and enables to adjust the output voltage.
Version | Photo | Schematics | Stock |
---|---|---|---|
V1.0 | HEB-inverter Schematic PDF | 16fully mounted |
Dead time
The dead time estimation for the H-Brige has been setimated by augmenting it an monitoring the power consumption of the system. The daead time was given by a counter clocked at 66 MHZ, but with a different number of bits for each measure.
bit nb | dead time [ns] | current [mA] |
---|---|---|
3 | 121 | 860 |
4 | 242 | 170 |
5 | 485 | 75 |
5 | 970 | 70 |