PIC18LF26K83

Configuration

Clock is set to the highest value (64MHz) as the board is made for test purposes. It could be lowered if a such speed is not needed for the final use. Typically in order to reduce power consumption

CAN

As described in the ADCS control document, the CAN configuration is the following : version 2.0 B, extended ID, SP set to 87.5% and SJW = 1, bus speed 125 kbps.

Register Hex Parameter Description
BRGCON1 0x0F BRP (2x16)/FOSC
SJW 1 x TQ
BRGCON2 0xBC PRSEG 5 x TQ
SAM once at sample point
SEG1PH 8 x TQ
SEG2PHTS Freely programmable
BRGCON3 0x01 SEG2PH 2 x TQ
WAKDIS Enable CAN wake-up
WAKFIL CAN line filter not used